{"created":"2023-05-15T16:14:11.605154+00:00","id":44736,"links":{},"metadata":{"_buckets":{"deposit":"b9a9cfd9-3935-47c6-9e68-9ee6e5357903"},"_deposit":{"created_by":25,"id":"44736","owners":[25],"pid":{"revision_id":0,"type":"depid","value":"44736"},"status":"published"},"_oai":{"id":"oai:shinshu.repo.nii.ac.jp:00044736","sets":["2668"]},"author_link":["173595","173607","173598","173604","173601","173600","173597","173608","173602","173599","173605","173603","173606","173596"],"item_20002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The research study on the influence of interfering with proper placement and guidance on wearing of respirator"}]},"item_20002_biblio_info_27":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"85","bibliographicPageStart":"81","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"信州公衆衛生雑誌"}]}]},"item_20002_creator_3":{"attribute_name":"作成者(その他言語)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"水木, 将"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"伊東, 黄"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"梅原, 舞"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小林, 若菜"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐藤, 渉"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"辻野, 亮"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤田, 楓"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"堀谷, 勇介"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"米良, 健輝"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"森下, 開"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"長谷川, 航平"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"塚原, 照臣"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"野見山, 哲生"}],"nameIdentifiers":[{}]}]},"item_20002_date_19":{"attribute_name":"日付","attribute_value_mlt":[{"subitem_date_issued_datetime":"2019-09-10","subitem_date_issued_type":"Created"}]},"item_20002_description_14":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"目的:呼吸用保護具は作業管理の1 つとして有効な対策である。しかし呼吸用保護具は不適切な装着により、保護具の効果が十分に発揮できない可能性がある。今回、労働者が業務上行う動作や装着指導が、呼吸用保護具の適切な装着に与える影響を調査した。方法:調査対象は、呼吸用保護具の装着経験のない大学生8 名とした。呼吸用保護具は、防じん機能を有する防毒マスクを用いた。装着評価は、マスク内外の粉じん濃度の比を計測する漏れ率を用いた。測定項目は、座位、発声、首の動き、歩行、走行の5 種類の動作に伴う漏れ率とし、装着指導前後による差を比較した。結果:解析対象は全データが入手できた6 名とした。装着の指導前のマスクの漏れ率は、座位と比し発声80 dB で有意に大きかった(p=0.03)。指導後のマスクの漏れ率は座位と比し発声80 dB で有意に大きく(p<0.05)、音量が大きくなると共に漏れ率が有意に大きくなった(p=0.01)。首の動き、歩行、走行は座位と差が無かった。また、指導前と指導後の座位同士、発声同士の漏れ率を比較すると、指導後で有意あるいは有意に近く低下した。考察:マスクの装着指導によって漏れ率が低くなった。発声は、80 dB で漏れ率が高くなり、比較的騒音レベルの高い職場での漏れ率の増加が懸念された。マスクを装着して作業に従事した際、大きな声を出した場合、再度マスクの装着状況の確認、再装着が必要である。","subitem_description_type":"Other"}]},"item_20002_description_20":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_20002_description_22":{"attribute_name":"その他の資源識別子","attribute_value_mlt":[{"subitem_description":"信州公衆衛生雑誌 13(2): 81-85(2019)","subitem_description_type":"Other"}]},"item_20002_full_name_16":{"attribute_name":"公開者(その他言語)","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"信州公衆衛生学会"}]}]},"item_20002_identifier_23":{"attribute_name":"資源識別子URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/10091/00021617"}]},"item_20002_source_id_25":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1882-2312","subitem_source_identifier_type":"ISSN"}]},"item_20002_source_id_26":{"attribute_name":"処理レコードID(総合目録DB)","attribute_value_mlt":[{"subitem_source_identifier":"AA12486936","subitem_source_identifier_type":"NCID"}]},"item_20002_version_type_51":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://soar-ir.repo.nii.ac.jp/?action=repository_action_common_download&item_id=20860&item_no=1&attribute_id=65&file_no=1"}}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"呼吸用保護具","subitem_subject_scheme":"Other"},{"subitem_subject":"respirator","subitem_subject_scheme":"Other"},{"subitem_subject":"漏れ率","subitem_subject_scheme":"Other"},{"subitem_subject":"leakage","subitem_subject_scheme":"Other"},{"subitem_subject":"フィットテスト","subitem_subject_scheme":"Other"},{"subitem_subject":"fit test","subitem_subject_scheme":"Other"},{"subitem_subject":"装着指導","subitem_subject_scheme":"Other"},{"subitem_subject":"guidance on wearing","subitem_subject_scheme":"Other"},{"subitem_subject":"発声","subitem_subject_scheme":"Other"},{"subitem_subject":"vocalization","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"呼吸用保護具の適切な装着を阻害する要因の検討と装着指導の効果に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"呼吸用保護具の適切な装着を阻害する要因の検討と装着指導の効果に関する研究"}]},"item_type_id":"20002","owner":"25","path":["2668"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-09-04"},"publish_date":"2020-09-04","publish_status":"0","recid":"44736","relation_version_is_last":true,"title":["呼吸用保護具の適切な装着を阻害する要因の検討と装着指導の効果に関する研究"],"weko_creator_id":"25","weko_shared_id":-1},"updated":"2023-05-15T18:12:28.729522+00:00"}