{"created":"2023-05-15T16:10:07.773879+00:00","id":40388,"links":{},"metadata":{"_buckets":{"deposit":"ab09c63f-2320-4c00-ac07-84ceefac941c"},"_deposit":{"created_by":25,"id":"40388","owners":[25],"pid":{"revision_id":0,"type":"depid","value":"40388"},"status":"published"},"_oai":{"id":"oai:shinshu.repo.nii.ac.jp:00040388","sets":[]},"author_link":["159476","159473","159472","159475","159474","159477","159478","159479","159471"],"item_20002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A Progress Report on Clinically Applied Cases of Al_2O_3 Ceramic Implant"}]},"item_20002_biblio_info_27":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1988-04-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"104","bibliographicPageStart":"92","bibliographicVolumeNumber":"14","bibliographic_titles":[{"bibliographic_title":"松本歯学"},{"bibliographic_title":"Journal of the Matsumoto Dental University Society","bibliographic_titleLang":"en"}]}]},"item_20002_creator_3":{"attribute_name":"作成者(その他言語)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"片岡, 滋"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"石原, 善和"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"片岡, 滋"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"石原, 善和"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"岩井, 啓三"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"平野, 龍紀"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"竹内, 利之"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"甘利, 光治"}],"nameIdentifiers":[{}]}]},"item_20002_date_19":{"attribute_name":"日付","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-03-04","subitem_date_issued_type":"Created"}]},"item_20002_description_14":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"During the last three years we have tested the clinical application of Al_2O_3 ceramic implant (Bioceram^[○!R]) at the Second Prosthodontics Department of Matsumoto Dental College. To examine the progress of 13 such cases, we made observations with the naked eye and x-rays ; in one of the cases, we also examined the progressive change of mas ticatory function. The following results were obtained: 1. Implants were applied in 12 patients (the same number of males and females, aged 20-50), in which 8 out of 20 implants were used for the lower posterior free end region where teeth were missing, the greatest percentage of the whole number, and ll implants of W type were used, the greatest percentage of the number of implants by types. 2. We could not find any case in which implants became detached, and satisfactory results were obtained in all cases on the whole. 3. In the case in which we made continual observations of masticatory function, the following results were obtained: 1) Our observations of masticatory function by standardized x-ray technique 6 months after implantation were satisfactory. 2) We could find nothing unusual in masticatory function examined with Mandibular Kinesiograph before treatment and 6 months after implantation. 3) We examined masticatory function using Lissajous figures from integrated EMGs, Changes in the electrical activitys of the muscles on the side of the implant occurred over time and vaired for different foods. 4) By measuring the individual biting forces 6 months after implantation it was found that the biting force of 76 (the implant denture) was stronger than that of 67.","subitem_description_type":"Other"}]},"item_20002_description_21":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_20002_full_name_16":{"attribute_name":"公開者(その他言語)","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"松本歯科大学学会"}]}]},"item_20002_identifier_23":{"attribute_name":"資源識別子URI","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"http://id.nii.ac.jp/1070/00002459/"}]},"item_20002_source_id_25":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_20002_source_id_26":{"attribute_name":"処理レコードID(総合目録DB)","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_20002_version_type_51":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://mdu.repo.nii.ac.jp/?action=repository_action_common_download&item_id=2468&item_no=1&attribute_id=22&file_no=1"}}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Al_2O_3セラミックインプラント材","subitem_subject_scheme":"Other"},{"subitem_subject":"インプラント義歯","subitem_subject_scheme":"Other"},{"subitem_subject":"筋電図","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Al_2O_3セラミックインプラント材の臨床応用例に関する経過報告","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Al_2O_3セラミックインプラント材の臨床応用例に関する経過報告"}]},"item_type_id":"20002","owner":"25","path":["2427"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-11-10"},"publish_date":"2022-11-10","publish_status":"0","recid":"40388","relation_version_is_last":true,"title":["Al_2O_3セラミックインプラント材の臨床応用例に関する経過報告"],"weko_creator_id":"25","weko_shared_id":25},"updated":"2023-05-15T18:11:09.327794+00:00"}