{"created":"2023-05-15T15:58:14.266644+00:00","id":27571,"links":{},"metadata":{"_buckets":{"deposit":"dcf25237-9a79-4e1f-ad53-501b994bb0f7"},"_deposit":{"created_by":3,"id":"27571","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"27571"},"status":"published"},"_oai":{"id":"oai:shinshu.repo.nii.ac.jp:00027571","sets":["2668"]},"author_link":["108704","108699","108701","108703","108702","108697","108700","108698"],"item_20002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The Installation of Automated External Defibrillators at Hospitals in Nagano Prefecture"}]},"item_20002_biblio_info_27":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"386","bibliographicPageStart":"379","bibliographicVolumeNumber":"54","bibliographic_titles":[{"bibliographic_title":"信州医学雑誌"}]}]},"item_20002_creator_3":{"attribute_name":"作成者(その他言語)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩下, 具美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"二木, 智子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"関口, 幸男"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"今村, 浩"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"手塚, 理絵"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"飯ケ濱, 実"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"岡元, 和文"}],"nameIdentifiers":[{}]}]},"item_20002_date_19":{"attribute_name":"日付","attribute_value_mlt":[{"subitem_date_issued_datetime":"2015-09-24","subitem_date_issued_type":"Created"}]},"item_20002_description_14":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Ventricular fibrillation (VF) is the main cause of sudden cardiac arrest. Because the mortality rate of patients with VF is extremely time-dependent, it is essential to perform defibrillation without delay. The automated external defibrillator (AED) is an instrument that laypeople can use anytime and anywhere. We surveyed the installation of AEDs in the 138 hospitals in Nagano Prefecture, and received 113 replies from the 138 hospitals. Fifty-nine hospitals (52%) have installed AEDs. Out of these 59, 28 hospitals experienced 31events of cardiopulmonary arrest in which AEDs were used in 24 of the events (77%).Ten of 13 patients with VF (77%) were successfully defibrillated. The more the installation rate of AEDs increases and AEDs are popularized, the more likely is the mortality rate to decrease.","subitem_description_type":"Other"}]},"item_20002_description_20":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_20002_description_21":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_20002_description_22":{"attribute_name":"その他の資源識別子","attribute_value_mlt":[{"subitem_description":"信州医学雑誌 54(6): 379-386(2006)","subitem_description_type":"Other"}]},"item_20002_full_name_16":{"attribute_name":"公開者(その他言語)","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"信州医学会"}]}]},"item_20002_identifier_23":{"attribute_name":"資源識別子URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/10091/3697"}]},"item_20002_source_id_25":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0037-3826","subitem_source_identifier_type":"ISSN"}]},"item_20002_source_id_26":{"attribute_name":"処理レコードID(総合目録DB)","attribute_value_mlt":[{"subitem_source_identifier":"AN00120815","subitem_source_identifier_type":"NCID"}]},"item_20002_version_type_51":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://soar-ir.repo.nii.ac.jp/?action=repository_action_common_download&item_id=4225&item_no=1&attribute_id=65&file_no=1"}}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"automated external defibrillator","subitem_subject_scheme":"Other"},{"subitem_subject":"ventricular fibrillation","subitem_subject_scheme":"Other"},{"subitem_subject":"in-hospital cardiopulmonary arrest","subitem_subject_scheme":"Other"},{"subitem_subject":"resuscitation","subitem_subject_scheme":"Other"},{"subitem_subject":"installation","subitem_subject_scheme":"Other"},{"subitem_subject":"自動体外式除細動器","subitem_subject_scheme":"Other"},{"subitem_subject":"心室細動","subitem_subject_scheme":"Other"},{"subitem_subject":"院内心肺停止","subitem_subject_scheme":"Other"},{"subitem_subject":"蘇生","subitem_subject_scheme":"Other"},{"subitem_subject":"普及","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"長野県内の病院におけるAED 普及状況","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"長野県内の病院におけるAED 普及状況"}]},"item_type_id":"20002","owner":"3","path":["2668"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-09-01"},"publish_date":"2020-09-01","publish_status":"0","recid":"27571","relation_version_is_last":true,"title":["長野県内の病院におけるAED 普及状況"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-05-15T22:03:36.957101+00:00"}