{"created":"2023-05-15T15:50:27.049391+00:00","id":2515,"links":{},"metadata":{"_buckets":{"deposit":"eb96e5e6-877f-4e8b-ad6f-a88830c40b38"},"_deposit":{"created_by":3,"id":"2515","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2515"},"status":"published"},"_oai":{"id":"oai:shinshu.repo.nii.ac.jp:00002515","sets":[]},"author_link":["8464","8463","8460","8461","8462"],"item_20002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Clinical Evaluation and Cases of Endosseous Shape Memory Implant"}]},"item_20002_biblio_info_27":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1985-08-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1-2","bibliographicPageEnd":"135","bibliographicPageStart":"129","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"松本歯学"}]}]},"item_20002_creator_2":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"神谷, 光男"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鷹股, 哲也"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"福与, 碩夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"橋本, 京一"}],"nameIdentifiers":[{}]}]},"item_20002_date_19":{"attribute_name":"日付","attribute_value_mlt":[{"subitem_date_issued_datetime":"2012-05-24","subitem_date_issued_type":"Created"}]},"item_20002_description_14":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"The composition of the shape memory implat is Ni50at%-Ti. It has been reported by many authors that the formation of bone around this material is satisfactory in vivo and it is harmless in vitro. The operative technique of shape memory implant is as easy as the usual blade implant. Moreover, the occlusal supporting force increased extremely by shape memory effect. And the indications of dental implant will be developed by the non-anatomic occlusal form, which we used to the super-structure of shape memory implant, because of its excellent masticatory efficiency. As a result of clinical evaluation of this system, it is possible to indicate many types of edentulous cases, and is excellent in coparison with the usual endosteal implant.","subitem_description_type":"Other"}]},"item_20002_description_21":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_20002_full_name_16":{"attribute_name":"公開者(その他言語)","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"松本歯科大学学会"}]}]},"item_20002_identifier_23":{"attribute_name":"資源識別子URI","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"http://id.nii.ac.jp/1070/00001371/"}]},"item_20002_source_id_25":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1613","subitem_source_identifier_type":"ISSN"}]},"item_20002_source_id_26":{"attribute_name":"処理レコードID(総合目録DB)","attribute_value_mlt":[{"subitem_source_identifier":"AN00232590","subitem_source_identifier_type":"NCID"}]},"item_20002_version_type_51":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://mdu.repo.nii.ac.jp/?action=repository_action_common_download&item_id=1371&item_no=1&attribute_id=22&file_no=1"}}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"形状記憶効果","subitem_subject_scheme":"Other"},{"subitem_subject":"骨内インプラント","subitem_subject_scheme":"Other"},{"subitem_subject":"Ni-Ni合金","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"形状記憶効果をもつ骨内インプラントの臨床治験例及びその評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"形状記憶効果をもつ骨内インプラントの臨床治験例及びその評価"}]},"item_type_id":"20002","owner":"3","path":["2439"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-11-10"},"publish_date":"2022-11-10","publish_status":"0","recid":"2515","relation_version_is_last":true,"title":["形状記憶効果をもつ骨内インプラントの臨床治験例及びその評価"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-15T18:34:11.217336+00:00"}