WEKO3
アイテム
{"_buckets": {"deposit": "b0b992da-4c24-4c45-a0cf-57aa14fd7503"}, "_deposit": {"created_by": 3, "id": "31860", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "31860"}, "status": "published"}, "_oai": {"id": "oai:shinshu.repo.nii.ac.jp:00031860", "sets": ["2668"]}, "author_link": ["127885", "127883", "127886", "127884", "127882", "127887", "127881"], "item_20004_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "The Validity of Perioperative Normothermia in Bioclean Room"}]}, "item_20004_biblio_info_27": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "52", "bibliographicPageStart": "46", "bibliographicVolumeNumber": "29", "bibliographic_titles": [{"bibliographic_title": "信州大学医学部附属病院看護研究集録"}]}]}, "item_20004_creator_3": {"attribute_name": "作成者(その他言語)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "伊藤, 理恵子"}], "nameIdentifiers": [{"nameIdentifier": "127881", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮下, 素子"}], "nameIdentifiers": [{"nameIdentifier": "127882", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "百瀬, 里美"}], "nameIdentifiers": [{"nameIdentifier": "127883", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高山, 好子"}], "nameIdentifiers": [{"nameIdentifier": "127884", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "丸山, 貴美子"}], "nameIdentifiers": [{"nameIdentifier": "127885", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "深澤, 佳代子"}], "nameIdentifiers": [{"nameIdentifier": "127886", "nameIdentifierScheme": "WEKO"}]}]}, "item_20004_date_19": {"attribute_name": "日付", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2015-09-25", "subitem_date_issued_type": "Created"}]}, "item_20004_description_14": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "当手術部では電気毛布や温水循環式マット,サンステート[○!R]を使用し,患者の保温に努めている。しかし,垂直層流式フィルターモジュール方式のクリーンルームで,かつ保温が十分に出来ない側臥位手術の場合,他の手術室よりも著明な体温低下を認めることが多い。今回,他の方式の加温装置に比べ,加温能力が高いといわれている温風式加温装置(以下ベアーハガー[○!R])をクリーンルームで使用してみようと考えた。風速,風量の多いクリーンルームでの検討例がないため,今回クリーンルームの側臥位手術でも保温効果があるのか,電気毛布と比較検討した。結果,ベアーハガー[○!R]による加温は,クリーンルーム,側臥位手術における保温手段として有効であることが認められた。さらに,ベアーハガー[○!R]による加温は電気毛布使用による加温に比し,短時間手術においても効果的であることが認められた。", "subitem_description_type": "Other"}]}, "item_20004_description_20": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_20004_description_22": {"attribute_name": "その他の資源識別子", "attribute_value_mlt": [{"subitem_description": "信州大学医学部附属病院看護研究集録 29(1): 46-52(2000)", "subitem_description_type": "Other"}]}, "item_20004_full_name_16": {"attribute_name": "公開者(その他言語)", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "127887", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "信州大学医学部附属病院看護部"}]}]}, "item_20004_identifier_23": {"attribute_name": "資源識別子URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/10091/14975"}]}, "item_20004_source_id_25": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1343-3059", "subitem_source_identifier_type": "ISSN"}]}, "item_20004_source_id_26": {"attribute_name": "処理レコードID(総合目録DB)", "attribute_value_mlt": [{"subitem_source_identifier": "AA11387338", "subitem_source_identifier_type": "NCID"}]}, "item_20004_text_52": {"attribute_name": "機関ID", "attribute_value_mlt": [{"subitem_text_value": "17"}]}, "item_20004_text_53": {"attribute_name": "コンテンツID", "attribute_value_mlt": [{"subitem_text_value": "oai:soar-ir.repo.nii.ac.jp:00008514"}]}, "item_20004_text_54": {"attribute_name": "コンテンツ更新日時", "attribute_value_mlt": [{"subitem_text_value": "2020-08-03T06:54:36Z"}]}, "item_20004_version_type_51": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"download_preview_message": "", "file_order": 0, "filename": "", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"url": "https://soar-ir.repo.nii.ac.jp/?action=repository_action_common_download\u0026item_id=8514\u0026item_no=1\u0026attribute_id=65\u0026file_no=1"}, "version_id": ""}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "クリーンルーム", "subitem_subject_scheme": "Other"}, {"subitem_subject": "THA", "subitem_subject_scheme": "Other"}, {"subitem_subject": "温風式加温装置", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "クリーンルームにおける温風式加温装置の有効性の検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "クリーンルームにおける温風式加温装置の有効性の検討"}]}, "item_type_id": "20004", "owner": "3", "path": ["2668"], "permalink_uri": "https://shinshu.repo.nii.ac.jp/records/31860", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-09-02"}, "publish_date": "2020-09-02", "publish_status": "0", "recid": "31860", "relation": {}, "relation_version_is_last": true, "title": ["クリーンルームにおける温風式加温装置の有効性の検討"], "weko_shared_id": 3}
クリーンルームにおける温風式加温装置の有効性の検討
https://shinshu.repo.nii.ac.jp/records/31860
https://shinshu.repo.nii.ac.jp/records/318600ed006b1-eaa0-48d4-bcd4-15fe028c94c8
名前 / ファイル | ライセンス | アクション |
---|---|---|
https://soar-ir.repo.nii.ac.jp/?action=repository_action_common_download&item_id=8514&item_no=1&attribute_id=65&file_no=1
|
|
Item type | Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-09-02 | |||||
タイトル | ||||||
タイトル | クリーンルームにおける温風式加温装置の有効性の検討 | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | The Validity of Perioperative Normothermia in Bioclean Room | |||||
作成者(その他言語) |
伊藤, 理恵子
× 伊藤, 理恵子× 宮下, 素子× 百瀬, 里美× 高山, 好子× 丸山, 貴美子× 深澤, 佳代子 |
|||||
公開者(その他言語) | ||||||
姓名 | 信州大学医学部附属病院看護部 | |||||
書誌情報 |
信州大学医学部附属病院看護研究集録 巻 29, 号 1, p. 46-52, 発行日 2000-03 |
|||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | クリーンルーム | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | THA | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 温風式加温装置 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 当手術部では電気毛布や温水循環式マット,サンステート[○!R]を使用し,患者の保温に努めている。しかし,垂直層流式フィルターモジュール方式のクリーンルームで,かつ保温が十分に出来ない側臥位手術の場合,他の手術室よりも著明な体温低下を認めることが多い。今回,他の方式の加温装置に比べ,加温能力が高いといわれている温風式加温装置(以下ベアーハガー[○!R])をクリーンルームで使用してみようと考えた。風速,風量の多いクリーンルームでの検討例がないため,今回クリーンルームの側臥位手術でも保温効果があるのか,電気毛布と比較検討した。結果,ベアーハガー[○!R]による加温は,クリーンルーム,側臥位手術における保温手段として有効であることが認められた。さらに,ベアーハガー[○!R]による加温は電気毛布使用による加温に比し,短時間手術においても効果的であることが認められた。 | |||||
日付 | ||||||
日付 | 2015-09-25 | |||||
日付タイプ | Created | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
その他の資源識別子 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州大学医学部附属病院看護研究集録 29(1): 46-52(2000) | |||||
資源識別子URI | ||||||
識別子 | http://hdl.handle.net/10091/14975 | |||||
識別子タイプ | HDL | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1343-3059 | |||||
処理レコードID(総合目録DB) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11387338 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |