WEKO3
アイテム
{"_buckets": {"deposit": "e1854e2f-9230-4234-bd5d-fa32f074e4ec"}, "_deposit": {"created_by": 3, "id": "31767", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "31767"}, "status": "published"}, "_oai": {"id": "oai:shinshu.repo.nii.ac.jp:00031767", "sets": ["2668"]}, "author_link": ["127424", "127426", "127425", "127427", "127428"], "item_20004_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "condensation of the ventilator circuit and contaminated circuit"}]}, "item_20004_biblio_info_27": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "109", "bibliographicPageStart": "104", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "信州大学医学部附属病院看護研究集録"}]}]}, "item_20004_creator_3": {"attribute_name": "作成者(その他言語)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "高尾, ゆきえ"}], "nameIdentifiers": [{"nameIdentifier": "127424", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "壬生, 菊代"}], "nameIdentifiers": [{"nameIdentifier": "127425", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石井, 留美子"}], "nameIdentifiers": [{"nameIdentifier": "127426", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林, 利江"}], "nameIdentifiers": [{"nameIdentifier": "127427", "nameIdentifierScheme": "WEKO"}]}]}, "item_20004_date_19": {"attribute_name": "日付", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2015-09-25", "subitem_date_issued_type": "Created"}]}, "item_20004_description_14": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "人工呼吸器加温加湿器のFisher\u0026Paykel社製のMR730を使用しFisher\u0026Paykel社製R206回路で、人工肺を用い各設定による回路内結露量を測定した。再生回路との結露量の差を調べた。又、回路汚染を調べた。206回路は、再生回路より結露が多く、チャンバー温は+設定にしない事が望ましい。患者の喀痰から検出された菌がチャンバーから検出された。回路汚染の予防には、結露を生じない設定と回路内の水分を排除し、逆流させない事が重要である。", "subitem_description_type": "Other"}]}, "item_20004_description_20": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_20004_description_22": {"attribute_name": "その他の資源識別子", "attribute_value_mlt": [{"subitem_description": "信州大学医学部附属病院看護研究集録 32(1): 104-109(2004)", "subitem_description_type": "Other"}]}, "item_20004_full_name_16": {"attribute_name": "公開者(その他言語)", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "127428", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "信州大学医学部附属病院看護部"}]}]}, "item_20004_identifier_23": {"attribute_name": "資源識別子URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/10091/15085"}]}, "item_20004_source_id_25": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1343-3059", "subitem_source_identifier_type": "ISSN"}]}, "item_20004_source_id_26": {"attribute_name": "処理レコードID(総合目録DB)", "attribute_value_mlt": [{"subitem_source_identifier": "AA11387338", "subitem_source_identifier_type": "NCID"}]}, "item_20004_text_52": {"attribute_name": "機関ID", "attribute_value_mlt": [{"subitem_text_value": "17"}]}, "item_20004_text_53": {"attribute_name": "コンテンツID", "attribute_value_mlt": [{"subitem_text_value": "oai:soar-ir.repo.nii.ac.jp:00008421"}]}, "item_20004_text_54": {"attribute_name": "コンテンツ更新日時", "attribute_value_mlt": [{"subitem_text_value": "2020-08-03T06:54:36Z"}]}, "item_20004_version_type_51": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"download_preview_message": "", "file_order": 0, "filename": "", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"url": "https://soar-ir.repo.nii.ac.jp/?action=repository_action_common_download\u0026item_id=8421\u0026item_no=1\u0026attribute_id=65\u0026file_no=1"}, "version_id": ""}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "人工呼吸器回路", "subitem_subject_scheme": "Other"}, {"subitem_subject": "加温加湿", "subitem_subject_scheme": "Other"}, {"subitem_subject": "回路汚染", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "人工呼吸器回路内結露と汚染について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "人工呼吸器回路内結露と汚染について"}]}, "item_type_id": "20004", "owner": "3", "path": ["2668"], "permalink_uri": "https://shinshu.repo.nii.ac.jp/records/31767", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-09-02"}, "publish_date": "2020-09-02", "publish_status": "0", "recid": "31767", "relation": {}, "relation_version_is_last": true, "title": ["人工呼吸器回路内結露と汚染について"], "weko_shared_id": 3}
人工呼吸器回路内結露と汚染について
https://shinshu.repo.nii.ac.jp/records/31767
https://shinshu.repo.nii.ac.jp/records/31767ed62cab0-b6a3-4b05-a872-e961a4f9ece0
名前 / ファイル | ライセンス | アクション |
---|---|---|
https://soar-ir.repo.nii.ac.jp/?action=repository_action_common_download&item_id=8421&item_no=1&attribute_id=65&file_no=1
|
|
Item type | Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-09-02 | |||||
タイトル | ||||||
タイトル | 人工呼吸器回路内結露と汚染について | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | condensation of the ventilator circuit and contaminated circuit | |||||
作成者(その他言語) |
高尾, ゆきえ
× 高尾, ゆきえ× 壬生, 菊代× 石井, 留美子× 小林, 利江 |
|||||
公開者(その他言語) | ||||||
姓名 | 信州大学医学部附属病院看護部 | |||||
書誌情報 |
信州大学医学部附属病院看護研究集録 巻 32, 号 1, p. 104-109, 発行日 2004-03 |
|||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 人工呼吸器回路 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 加温加湿 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 回路汚染 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 人工呼吸器加温加湿器のFisher&Paykel社製のMR730を使用しFisher&Paykel社製R206回路で、人工肺を用い各設定による回路内結露量を測定した。再生回路との結露量の差を調べた。又、回路汚染を調べた。206回路は、再生回路より結露が多く、チャンバー温は+設定にしない事が望ましい。患者の喀痰から検出された菌がチャンバーから検出された。回路汚染の予防には、結露を生じない設定と回路内の水分を排除し、逆流させない事が重要である。 | |||||
日付 | ||||||
日付 | 2015-09-25 | |||||
日付タイプ | Created | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
その他の資源識別子 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州大学医学部附属病院看護研究集録 32(1): 104-109(2004) | |||||
資源識別子URI | ||||||
識別子 | http://hdl.handle.net/10091/15085 | |||||
識別子タイプ | HDL | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1343-3059 | |||||
処理レコードID(総合目録DB) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11387338 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |